CT PT Testing

  • MCVT405  CT/PT Analyzer

    MCVT405 CT/PT Analyzer

    Turn ratio test.

    Ratio error and phase angle error test.

    Secondary burden test.

    Nameplate guess.

    CT residual magnetism determination and demagnetization.

    Polarity check.

    ALF & FS.

  • CT/PT Analyzer MCVT01C

    CT/PT Analyzer MCVT01C

    Turn ratio test.

    Ratio error and phase angle error test.

    Secondary burden test.

    Polarity check.

  • Portable Capacitance PT Test Equipment MCVT01

    Portable Capacitance PT Test Equipment MCVT01

    Adopting indirect method to realize test of ratio, ratio error and phase angle error, and etc.

    Through Ratio and admittance test, calculate out the error of 80%-120% rated voltage under rated burden and lower limit burden.

    Small size and light weight, suitable for field test of Capacitance PT.

    Voltage ratio test.

     

  • CT Burden FY series

    CT Burden FY series

    Wide operation range

    Accuracy: ±3%

    Applicable standard: IEC60044-2 or ANSI/IEEE C57.13

    Multi-type operation mode optional: touch screen, button selector and knob switch

  • Portable Electronic (Digital) CT/VT Calibrator HEWD-2A

    Portable Electronic (Digital) CT/VT Calibrator HEWD-2A

    Digital Output Error Test  (Ratio Error and Phase Error).

    Compatible with protocol IEC61850-9-1/2/2LE and IEC60044-FT3.

    Analog Output Error Test (Ratio Error and Phase Error).

    Analog of small signal output.

    EMC compliance with standard IEC60044-8.

  • PT Burden FY series

    PT Burden FY series

    1. Wide operation range

    2. Accuracy: ±3%

    3. Applicable standard: IEC60044-2 or ANSI/IEEE C57.13

    4. Multi-type operation mode optional: touch screen, button selector and knob switch

  • Standard CT With Current Generator HLS series

    Standard CT With Current Generator HLS series

    High accuracy.

    5 to 4000A current transformer design (or according to client requirement).

    Used for precision measurement of calibration of instrument CT.

    With facility to test the performance of CT and verify its own accuracy.

    Can integrate with current source.

  • CT & PT Test Bench

    CT & PT Test Bench

    Ratio Error and Phase angle error test

    High and stable test data accuracy

    Open-circuit & close-circuit demagnetization function

    With over current, over voltage, reverse polarity, overload and wrong wiring protection

    Applicable standard:  IEC 60044 or ANSI/IEEE C57.13  (depends on customer’s requirements)

  • Standard Current Transformer HLB-32G series

    Standard Current Transformer HLB-32G series

    5-3200A current transformer design.

    Adopting two stage principles to ensure excellent accuracy.

    Accuracy class: 0.005.

    Operating range: (1-120%)In.

    Approx 50kgs.

    Current transformer integrated with source can be optional.

  • Resonant High Voltage Source System

    Resonant High Voltage Source System

    Can work together with High Voltage Standard PT

    Big rated capacity and stable output

    With Over current & over voltage protection function

    Fine & coarse adjustment

  • Double Stage Standard Current Transformer BL258H

    Double Stage Standard Current Transformer BL258H

    High accuracy, can be up to class 0.002.

    5 to 5000A current transformer design (or according to client requirement).

    Used for precision measurement of calibration of instrument CT.

    Integrated with current source (optional).

    Double stage burden ±2.5±j2.5mΩ.

  • Inductive Voltage Divider HJF1

    Inductive Voltage Divider HJF1

    Portable Type, easy to carry.

    Can work as one part of CT PT test system.

    Can be used as other purpose.

    Accuracy class: 0.005.