Single Phase Portable Meter Test System MCCS1.1

Small size and weight.

Used in lab or worksite.

LCD display.

Accuracy class: 0.1 (direct mode); 0.2 (clamp mode).

Measuring range: upto 300V /100A (direct mode).

Power and Energy test, Demand test, Error test, Dial test, Start, Creep test.

Support RS232 communication with PC to upload the test data.


Features

Technical Index

1. Standard meter integrated with voltage source and current source.

2. 7” touch screen LCD.  ARM in-built system.

3. Output with high stability and low distortion.

4. Four working mode:

-Portable single phase meter test equipment (optional: three position mount rack).

-Portable single phase reference standard meter.

-Portable single phase meter tester with current source.

-Standard meter which can give output impulse for calibration of the unit.

5. With enough protection: current open, current over load, voltage short and etc.

6. Can do below test: start test, creep test, basic error test, standard deviation tester, dial test, etc.

7. Can do voltage dip test and power interrupt test and power ramp up and down test.

8. 2-21 times harmonic; can set amplitude and phase; and do harmonic analyze and get waveform.

9. With self-test function namely can perform monitoring of output voltage, output current, output phase, power factor, output frequency, output harmonic waveform and power output stability and etc.

Single Phase Portable Meter Test System MCCS1.1 (2)
Single Phase Portable Meter Test System MCCS1.1 (1)

  • Previous:
  • Next:

  • Accuracy class of direct mode 0.1
    Accuracy class (clamp 10A, 50A, 100A, 300A…optional) 0.2
    Technical index of in-built single phase standard meter
     Class 0.1
    Input current range 0.025A, 0.05A, 0.1A, 0.25A, 0.5A, 1A, 2.5A, 5A, 10A, 20A, 50A, 100A
    Input voltage range up to 300V
    Display resolution 6 digits (valid)
    Output voltage up to 240V, 120% adjustable (maximum up to 288V)
    Adjust resolution better than 0.01%
    Output current range 0.05A, 0.25A, 1A, 5A, 20A, 100A
    0-120% adjustable;
    Adjust resolution better than 0.01%
    Minimum output current 1mA (≤5%)
    Output power 30VA for current and 50VA for voltage (only test one meter)
    100VA for current and 50VA for voltage (test three meters at the same time)
    Output stability of voltage, current and power ≤0.05% /120s
    Waveform distortion of output voltage/current ≤0.5%
    Frequency range 45-65HZ
    Adjust resolution 0.01Hz
    Phase angle range -180.0o ~180.0o
    Adjust resolution 0.01°
    Power supply AC 220V±10%,50/60HZ; or from measuring circuit
    Power consumption 200VA (maximum)
    Dimension & Weight 361*236*163mm & 7kg (main unit)