Three Phase Meter Test Bench

1. Error test, start test, creep test, standard deviation test..etc

2. Measurement of volts, current, p.f., power, frequency, phase angle, harmonic..etc..

3. Power Source (PS): output 0-360V/phase & 1mA-120A/phase, or depend on client requirement

4. Standard Reference Meter (SRM): accuracy class (0.02, 0.05 or 0.1) is optional

5. Can be independent set & output of each phase voltage & current

6. Can set phase angle independently

7. Meter Rack: positions (3, 6, 10, 12, 20, 24,40..) are optional

8. Automatic control by PC software

9. Manual control by touch screen


Features

Technical Specifications


  • Previous:
  • Next:

  • Accuracy class of Reference Standard Meter: 0.05 or 0.02 (optional)

    Output Voltage:

    Ranges: 3 x (0-480V) (or following customer requirement),  0 ~ 120% adjustable

    Resolution: 0.01%

    Distortion: ≤ 0.5%

    Output Stability: ≤0.05% or 0.02% /3minutes      

    Capacity: 50VA/position (depends on meter position quantity and customer requirements)

    Output Phase angle:

    Adjustment range: 0° ~ 360°

    Resolution: 0.01°

    Output current:

    Adjustment range: 3 x (1mA ~ 100A), 0-120%

    adjustable.

    Resolution: 0.01%

    Distortion: ≤ 0.5%

    Output Stability: ≤0.05% or 0.02%/3minutes

    Capacity: 100VA/position (depends on meter position quantity and customer requirement and with ICTs or not)

    Output frequency

    Adjustment range: 45Hz ~ 65Hz

    Resolution: 0.01Hz

    Others

    Time base: 1 ~ 9999s

    Insulation between Voltage circuit vs. Current circuit, Between circuits vs. Earth: ≥ 5MΩ

    Power supply: 240V or 3×240V/415V±10%, 50/60Hz±10%

    Ambient conditions: Temperature 50C ~ 400C

    Relative humidity: up to 90%

    Configurations

    1. Three phase Power source (PS)

    2. Three phase Standard reference meter (SRM), class 0.05 or 0.02

    3. The Rack

    ● Number of positions: 3, 6, 10, 12, 20, 24, 32 (or customer requirement)

    ● Number of positions (with ICT):  maximum 20 positions and depend on customer requirement

    ● Each rack equip 1 emergency STOP switch

    ● Each posistion consist of: 1 QCD 6/8/10 pins + 1 scanning head + 1 meter clamping + 1 RS/232/485 communication port + 1 error display + 1 RESET button + 1 Set of voltage cable+1 ICT (need ICT or not  depends on customer)

    4. Control software

    5. Manual control keyboard

    6. Details operation manual including PC software manual

    7. Optional

    ● Isolated Current Transformer (ICT)

    Accuracy class: 0.01% (0.5C-1-0.5L)

    Current Ratio: 1:1 (1mA-120A)

    Current output: 3*(0.001-120)A  (both primary and secondary)

    Secondary Output load: Maximum 0.5V (output current 1mA-120A)

    ● Personnel Computer

    ● Printer